R&D and Technology
Corporate R&D CENTER & FORMULATION LABORATORY

R&D and Technology

Formulation development tailored to stone characteristics and oven curing regimes.

Test Standard

ASTM D2196

Rheology and CPS viscosity control

Process Compatibility

5 Cure Regime

Decker, tunnel, microwave, vacuum, natural

Surface Protection

UV & Heat Resistance

Yellowing control in beige and white stones

Product Ecosystem

70+ Solutions

Epoxy, gel, polyester and abrasive series

R&D and Technology industrial view
APOX KIMYA · R&D AND TECHNOLOGY SINCE 2013

R&D CENTER & FORMULATION LABORATORY

Formulation development tailored to stone characteristics and oven curing regimes.

Low viscosity resin advancement in microcracks
PENETRATION TEST

Low viscosity resin advancement in microcracks

Special series with high brightness and UV resistance
DIAMOND & BLUETECH

Special series with high brightness and UV resistance

Our Corporate Approach

Resin engineering specific to the mineralogical structure of the stone and the kiln regime.

Every natural stone group exhibits distinct behavior in terms of pore structure, color tone, moisture level, and processing temperature.

Our R&D approach focuses on achieving the optimal balance of penetration, yellowing resistance, and bond strength across natural curing, multi-deck oven, tunnel oven, microwave, and vacuum applications.

Every marble, granite, travertine and onyx block in natural stone processing lines; It has a unique character in terms of capillary crack depth, pore distribution, moisture content and thermal conductivity. Epoxy, gel and polyester systems developed in APOX Kimya R&D laboratory; It is optimized according to the actual operating parameters of the stone and kiln line rather than standard uniform solutions.

Viscosity (CPS) measurements, gel time (pot-life) analyses, exothermic reaction curves and UV/heat-induced yellowing resistance tests in ASTM D2196 standards constitute the basic verification steps of each new formulation. In this way, deep penetration and high mechanical bond strength are achieved in deck oven, tunnel oven, microwave, vacuum and natural curing processes.

Low Viscosity & Capillary Progress

High penetration resin architecture that penetrates deep into microcracks.

Optik Netlik & Sararma Direnci

Stabilizers that prevent stains, shadows and color changes in light-colored marble and crystalline stones.

Oven Regime Synchronization

Gel and cure profile compatible with target time from 40°C deck ovens to microwave lines.

Field & Sample Verification

Laboratory testing on the customer's own stone sample and line commissioning support.

Ar-Ge Metodolojisi

Formulation development in 4 steps from laboratory to production line.

Contact our technical team
Stone & Process Analysis
STEP 01

Stone & Process Analysis

The pore structure, moisture status, color of the stone to be processed and the factory's oven temperature/time are examined in detail.

Standard Procedure 01 / 04
Polymer & Hardener Design
STEP 02

Polymer & Hardener Design

The resin system is formulated according to the targeted CPS viscosity, mixing ratio (4:1, 3:1 etc.) and gel time.

Standard Procedure 02 / 04
Curing & Strength Tests
STEP 03

Curing & Strength Tests

Furnace simulation, tensile-rupture strength, gloss contribution and thermal shock resistance are verified in the laboratory.

Standard Procedure 03 / 04
Industrial Site Verification
STEP 04

Industrial Site Verification

Performance and consumption efficiency are confirmed by serial application on the production line, accompanied by our technical team.

Standard Procedure 04 / 04

Our Basic Principles

R&D and Technology are the building blocks of our approach.

Formulation Engineering
01 / STANDART R&D and Technology

Formulation Engineering

Resin-hardener systems are optimized for low viscosity, rapid curing, and high mechanical bond strength.

APOX Quality Assurance
Surface & Stone Compatibility
02 / STANDART R&D and Technology

Surface & Stone Compatibility

Dedicated studies are conducted to minimize staining, shadowing, or yellowing risks on beige, white, grey, and crystalline stones.

APOX Quality Assurance
Sample & Application Validation
03 / STANDART R&D and Technology

Sample & Application Validation

Our technical team performs hands-on application assessments to select the ideal product for each client’s process.

APOX Quality Assurance

Equivalent on the Field

Our product groups brought to life by this discipline

Open the entire product catalog
Let’s determine the right product for your project together.

Technical Solution Desk

Let’s determine the right product for your project together.

Consult our technical team regarding surface type, application process, and product line.

Cookie & Privacy Preferences

We only use strictly necessary technical storage to ensure security. Analytics, functional, and marketing cookies are disabled by default — zero tracking cookies are loaded without your explicit consent. Cookie Policy · Privacy & Data Protection Notice